Pneumatic actuation for VDV valves
Our pneumatic-actuator program covers packages for valve sizes approximately DN8–DN200, with an air-supply range of 2.5–8 bar depending on actuator size and duty. Both double-acting and spring-return arrangements are available. The actuator is sized from actual valve torque, supply pressure, required safety factor, cycle rate and fail position—not only from nominal valve size.
Single-acting versus double-acting
A double-acting actuator uses air for both opening and closing and is efficient where a defined fail position is not required. A spring-return actuator uses stored spring force for a fail-open or fail-closed action when air is lost. The spring package changes available torque, so minimum site air pressure must be stated when sizing.
Accessory packages
Typical automation accessories include solenoid valves, filter/regulator air preparation, open/closed limit-switch boxes and positioners. Control options include common 4–20 mA and 0–10 V positioner signals. Accessory voltage, enclosure rating, hazardous-area requirement and communication preference should be defined at quotation stage.
Package integration and verification
When supplied with a valve, the mounting bracket, stem coupling, travel stops and open/closed indication are checked as one assembly. Functional inspection can include stroke direction, fail action, air connections, switch feedback and positioner response where specified.
What to send for quotation
Provide the valve model/size, maximum differential pressure, available air pressure, fail-open/fail-closed/no-fail requirement, cycle rate, control signal, accessory voltage and environmental classification. For modulating service, include expected control frequency and positioning requirement.
Original VDV pneumatic-actuator operating and accessory notes
The legacy VDV documentation distinguishes double-acting air-to-open/air-to-close from single-acting spring-return arrangements. It gives a two-position five-port solenoid as a typical double-acting selection and a two-position three-port solenoid for spring return; final valve/actuator specifications govern.
Air filter/regulator/lubrication assemblies, remote limit switches and 4–20 mA or 0–10 V positioners are optional, not standard. The archived operating diagram has Chinese labels; R85 and R115 photographs illustrate alternative bodies. Specify explosion-protection rating where required.
Inspection evidence to specify
- Valve type, size (DN/NPS), pressure class and end connections
- Medium, operating temperature, materials and sealing requirements
- Actuator/control, duty cycle and fail position where applicable
- Order quantity, required tests and documentation; drawings for custom parts
For an existing complete valve, a CAD drawing is optional. Use the message box to give the service and configuration details below; send drawings for custom valve bodies.